Performance Testing
GCI entered into an agreement to perform 16 FGD scrubber performance tests for a major utility company in the South East. Each test program included the assessment of 7 emissions and performance guarantees including Sulfur Dioxide Removal Efficiency, Particulate Emissions, Gypsum Composition, FGD Purge Stream Consumption, Electrical Power Consumption, Limestone Consumption, and Forced Oxidation System Performance. Multiple inlets and outlets were sampled simultaneously by 11 GCI Crewmembers.
Stratification of Particulate Monitor Location
GCI completed the testing necessary for the installation of particulate monitors for one of the North East’s largest utility providers. Four crews were organized to test multiple points simultaneously so that 16 test points were sampled in duplicate to determine the stratification. GCI was able to complete 32, 30 minute test runs per day on 6 stacks. GCI’s laboratory technicians provided on-site recovery and analysis of the results.
Precision Flow©
Since its development, Precision Flow© test procedures and equipment have been used to measure flow in coal powered power plant stacks with greater accuracy and precision resulting in significant SO2 and NOx credits savings. GCI routinely performs flow RATAs with less than 2% RA if the previous RATA was performed with Precision Flow© or with other electronic flow systems. For a major Midwest Utility GCI adjusted CEMS curve settings utilizing Precision Flow© equipment on several coal fired plants resulting a savings of over $5 million annually with an expenditure of less than $200,000.
to Request a Quote or Testing Information. |